Determinación experimental y contraste numérico de la resistencia térmica de un muro de bloques de concreto hueco

Translated title of the contribution: Experimental determination and numerical contrast of thermal resistance in a hollow concrete block wall

Research output: Contribution to journalArticlepeer-review

5 Scopus citations

Abstract

This paper presents design and construction of an experimental test to determine the thermal resistance of a hollow concrete blocks wall, according to the international standard known as guarded hot plate. The construction procedure and implementation of the device are described, reproducing operations conditions for buildings located in warm dry climate, and the thermal resistance was experimentally and numerically determined. The results were found by applying controlled temperature differences on both sides of the wall between heating and cooling temperature zones, in steady state conditions. Experimental and numerical results show variations in the value of thermal resistance, ranging from 0.15 to 0.19 °C m2/W. Values of the thermal resistance were fitted to an empirical expression as function of the temperature difference between the walls and the average temperature of the wall.

Translated title of the contributionExperimental determination and numerical contrast of thermal resistance in a hollow concrete block wall
Original languageSpanish
Pages (from-to)163-176
Number of pages14
JournalInformacion Tecnologica
Volume21
Issue number6
DOIs
StatePublished - 2010

Fingerprint

Dive into the research topics of 'Experimental determination and numerical contrast of thermal resistance in a hollow concrete block wall'. Together they form a unique fingerprint.

Cite this