Influence of filling ratio and carrier type on organic matter removal in a moving bed biofilm reactor with pretreatment of electrocoagulation in wastewater treatment

C. Lopez-Lopez, J. Martín-Pascual, A. González-Martínez, K. Calderón, J. González-López, E. Hontoria, J. M. Poyatos

Research output: Contribution to journalArticleResearchpeer-review

8 Citations (Scopus)
Original languageEnglish
Pages (from-to)1759-1767
Number of pages9
JournalJournal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering
Volume47
Issue number12
DOIs
StatePublished - 1 Oct 2012
Externally publishedYes

Fingerprint

Biofilms
Wastewater treatment
Biological materials
Electrophoresis
Thermal gradients
Gels
Chemical oxygen demand
Bioreactors
Water resources
Pilot plants
Nutrients
Water quality
Wastewater
Genes
Proteobacteria

Keywords

  • carrier type
  • electrocoagulation
  • MBBR
  • urban wastewater

Cite this

@article{be1e401f9dc843a1b60793212d24272b,
title = "Influence of filling ratio and carrier type on organic matter removal in a moving bed biofilm reactor with pretreatment of electrocoagulation in wastewater treatment",
keywords = "carrier type, electrocoagulation, MBBR, urban wastewater",
author = "C. Lopez-Lopez and J. Mart{\'i}n-Pascual and A. Gonz{\'a}lez-Mart{\'i}nez and K. Calder{\'o}n and J. Gonz{\'a}lez-L{\'o}pez and E. Hontoria and Poyatos, {J. M.}",
year = "2012",
month = "10",
day = "1",
doi = "10.1080/10934529.2012.689223",
language = "Ingl{\'e}s",
volume = "47",
pages = "1759--1767",
journal = "J. Environ. Sci. Health A Tox. Hazard Subst. Environ. Eng",
issn = "1093-4529",
publisher = "Taylor and Francis Ltd.",
number = "12",

}

Influence of filling ratio and carrier type on organic matter removal in a moving bed biofilm reactor with pretreatment of electrocoagulation in wastewater treatment. / Lopez-Lopez, C.; Martín-Pascual, J.; González-Martínez, A.; Calderón, K.; González-López, J.; Hontoria, E.; Poyatos, J. M.

In: Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering, Vol. 47, No. 12, 01.10.2012, p. 1759-1767.

Research output: Contribution to journalArticleResearchpeer-review

TY - JOUR

T1 - Influence of filling ratio and carrier type on organic matter removal in a moving bed biofilm reactor with pretreatment of electrocoagulation in wastewater treatment

AU - Lopez-Lopez, C.

AU - Martín-Pascual, J.

AU - González-Martínez, A.

AU - Calderón, K.

AU - González-López, J.

AU - Hontoria, E.

AU - Poyatos, J. M.

PY - 2012/10/1

Y1 - 2012/10/1

KW - carrier type

KW - electrocoagulation

KW - MBBR

KW - urban wastewater

UR - http://www.scopus.com/inward/record.url?scp=84863749202&partnerID=8YFLogxK

U2 - 10.1080/10934529.2012.689223

DO - 10.1080/10934529.2012.689223

M3 - Artículo

VL - 47

SP - 1759

EP - 1767

JO - J. Environ. Sci. Health A Tox. Hazard Subst. Environ. Eng

JF - J. Environ. Sci. Health A Tox. Hazard Subst. Environ. Eng

SN - 1093-4529

IS - 12

ER -