Resumen
In the Research Center (CINVESTAV), located north Mexico City was evaluated a 60 kWp photovoltaic (PV) system. The PV system energy performance ratio, so called "quality factor" is reported together with the measured solar irradiation, ambient and PV module temperatures. The performance ratio (PR), defines the overall PV system performance considering operation parameters as the produced energy, the incident solar irradiance and the total effect of system losses. The electric grid-tied PV system consists of 240 PV modules of 250 Wp each, which are connected to 5 inverters to transform three phase AC. We describe the PV system electric performance for 36 consecutive months through diverse weather conditions. The calculated average PR was 86.8% for the 36 months, even though, it had a lower PR of about 84.8% in the last 12 months due to the PV array string outages and also inverter technical troubles. The average daily energy produced by the PV system in 3 years was 260.45 kWh/day and an average accumulated energy of 95,064.25 kWh per year.
Título traducido de la contribución | Rendimiento por 36 meses de un sistema fotovoltaico de 60 kWp en la ciudad de México |
---|---|
Idioma original | Inglés |
Páginas (desde-hasta) | 1017-1025 |
Número de páginas | 9 |
Publicación | Revista Mexicana de Ingeniera Quimica |
Volumen | 18 |
N.º | 3 |
DOI | |
Estado | Publicada - 1 sep. 2019 |
Nota bibliográfica
Publisher Copyright:© 2019, Universidad Autonoma Metropolitana Iztapalapa. All rights reserved.