T1 - Properties of the HPHT diamond when used as a soft X-Ray detector
AU - Melendrez-Amavizca, Rodrigo
AU - Diaz-Lagos, Mercedes
AU - Martinez-Ovalle, Segundo Agustin
N1 - Publisher Copyright:
© 2017. Acad. Colomb. Cienc. Ex. Fis. Nat.
PY - 2017/4
Y1 - 2017/4
N2 - The diamond has extraordinary physical and chemical properties. This material by having a Zeff (atomic number-cash) equivalent to the human tissue is converted into a material suitable for use as a dosimeter of radiation. In this work, the properties of response to Afterglow (AG), Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) in HPHT diamond type lb (high temperature and high pressure diamond) are studied when subjected to lightning X (0.75 mA, 35 kV). The properties dosimetric curve and the TL were obtained on a computer Riso TL/OSL, where studies of fading (fading thermoluminescent), show that after a time of 1 hour, it stabilizes the signal TL and the reproducibility presents an error signal is not greater 5%. It is linearity in the three techniques for absorbed dose between 0-2 Gy. Between 2-9 Gy can be considered a response supralineal for the three techniques used and obtained a saturation of the sample to the absorbed doses increased to 9 Gy. It is showed that this material presents a promising future as a dosimeter in clinical radiation beams soft, used especially for radiation dosimetry for clinical use.
AB - The diamond has extraordinary physical and chemical properties. This material by having a Zeff (atomic number-cash) equivalent to the human tissue is converted into a material suitable for use as a dosimeter of radiation. In this work, the properties of response to Afterglow (AG), Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) in HPHT diamond type lb (high temperature and high pressure diamond) are studied when subjected to lightning X (0.75 mA, 35 kV). The properties dosimetric curve and the TL were obtained on a computer Riso TL/OSL, where studies of fading (fading thermoluminescent), show that after a time of 1 hour, it stabilizes the signal TL and the reproducibility presents an error signal is not greater 5%. It is linearity in the three techniques for absorbed dose between 0-2 Gy. Between 2-9 Gy can be considered a response supralineal for the three techniques used and obtained a saturation of the sample to the absorbed doses increased to 9 Gy. It is showed that this material presents a promising future as a dosimeter in clinical radiation beams soft, used especially for radiation dosimetry for clinical use.
KW - Characteristics of the TL and OSL
KW - Diamond
KW - High pressure
KW - High temperature
KW - Properties dosimetric
UR - http://www.scopus.com/inward/record.url?scp=85130028514&partnerID=8YFLogxK
U2 - 10.18257/raccefyn.457
DO - 10.18257/raccefyn.457
M3 - Artículo
AN - SCOPUS:85130028514
SN - 0370-3908
VL - 41
SP - 168
EP - 173
JO - Revista de la Academia Colombiana de Ciencias Exactas, Fisicas y Naturales
JF - Revista de la Academia Colombiana de Ciencias Exactas, Fisicas y Naturales
IS - 159
ER -