TY - JOUR
T1 - Thermoluminescence α-Al2O3:C detectors (TLD-500K)
T2 - Some results of a long-term testing
AU - Pashchenko, L. P.
AU - Barboza-Flores, M.
N1 - Funding Information:
Acknowledgements--This work was supported in part by CONACyT (M6xico, Grant No. D 1520-E9201 ), DGICSA-SEP (M~xico), FOMES (Universidad de Sonora, M~xico), and the Third World Academy of Sciences (Italy).
PY - 1995/10
Y1 - 1995/10
N2 - Anion-defective α-Al2O3:C single crystals, commercially grown in Russia as TLD-500K detectors, have been increasingly used for environmental radiation measurements. These detectors have attracted great interest because of their high sensitivity and simple annealing procedure. The application of TLD for routine measurements in environmental monitoring, involving storage periods which may extend up to one year, imposes strict requirements on the fading, the change in sensitivity with long periods of time and other characteristics of the dosimeters. Many of these properties of TLD-500K have not yet been completely investigated and need to be further explored. This paper presents some results of long-term testing of the detectors. The variation in sensitivity within the detector group as well as changes of the sensitivity with time and number of read-outs were estimated. All tests were made by using low doses of irradiation, adequate for environmental dosimetry.
AB - Anion-defective α-Al2O3:C single crystals, commercially grown in Russia as TLD-500K detectors, have been increasingly used for environmental radiation measurements. These detectors have attracted great interest because of their high sensitivity and simple annealing procedure. The application of TLD for routine measurements in environmental monitoring, involving storage periods which may extend up to one year, imposes strict requirements on the fading, the change in sensitivity with long periods of time and other characteristics of the dosimeters. Many of these properties of TLD-500K have not yet been completely investigated and need to be further explored. This paper presents some results of long-term testing of the detectors. The variation in sensitivity within the detector group as well as changes of the sensitivity with time and number of read-outs were estimated. All tests were made by using low doses of irradiation, adequate for environmental dosimetry.
UR - http://www.scopus.com/inward/record.url?scp=0029389816&partnerID=8YFLogxK
U2 - 10.1016/1350-4487(95)00264-F
DO - 10.1016/1350-4487(95)00264-F
M3 - Artículo
SN - 1350-4487
VL - 24
SP - 427
EP - 429
JO - Radiation Measurements
JF - Radiation Measurements
IS - 4
ER -